Smoke Alarm Buying Guide

Which smoke alarms are suitable for which rooms?

When it comes to choosing smoke alarms (also known as smoke detectors) it can be difficult to choose the correct type of alarm to suit the particular area of your home, rented office or property. The manufacturers have created a variety of smoke detectors – and with very good reason! The right detector in every space will not only help reduce false alarms, but also help identify the fire dangers that are real. Below you’ll find the rooms listed along with the kind of sensor you must install along with a brief explanation of the reason.

Smoke alarms with ionisation (stairwells or landings offices):

Smoke detectors with ionisation have used in all kinds of homes for a long time. They are designed to respond quickly to fires that are rapidly flaming, Ionisation smoke detectors are the most sensitive to particles of a small size. When fires create only a little smoke however the fuel is fast burning and ionisation smoke detector is the most effective way to detect its presence. These fires usually come from the materials like clothes and paper.

If you’re not sure what kind of smoke alarm are using, look whether there is an active symbol or compartment within the alarm (if it is accessible). Contrary to optical smoke detectors smoke alarms with ionisation feature an extremely small radioactive source inside the sensor chamber , which allows the ionizing technology to function. Their rapid reaction to tiny particles could make the smoke alarm susceptible to alarms that are false, especially in areas near kitchens or windows that are open. Due to this, it is advised for Ionisation alarms to be placed in staircases, upstairs landings , and offices. This will prevent the possibility of alarms that are triggered while cooking or burning toast!

Click here for the best smoke alarms UK.

Smoke alarms with optical sensors (bedrooms and lounges, hallways along with office spaces or landings):

Optical smoke alarmsare sometimes referred to by the name of photoelectric detectors are more susceptible to alarm snoozes that are false than Ionisation models and are a little faster in identifying slow burning fires that produce lots of smoke. The fires usually originate from upholstery-type material or over heated wiring. The quick response to fires that are bubbling is due on the smoke detector’s optical superior sensitiveness to large particles that are in the air. The chamber’s optical sensor effectively “sees” the smoke present, since the massive particles block the view and cause Infrared-colored light that scatters.

Smoke detectors with optical sensors are ideal to be installed in bedrooms and living spaces where cables and soft furniture are commonplace. They are also able to be put in inside hallways that are downstairs since they are safer than Ionisation detectors that sound falsely in the event of cooking fumes emanating in the kitchen. However, optical alarms are not recommended for areas that are exposed to elements and dusty environments.

Heat alarms (kitchens, garages):

Alarms that respond to ambient temperature, instead of smoking they are perfect for installation in kitchens. They feature a thermistor that is fixed temperature that is activated when the temperature in the room is around 55 degrees. This particular heat sensing technique eliminates false alarms entirely since the device doesn’t respond to cooking fumes and steam. Certain models are also specifically designed to detect a rapid increase in temperature, referred to as the rate of rise technique to signal an alarm for rapidly flaming fires before the temperature threshold is attained. Be sure to follow the instruction of the manufacturer to determine the optimal ceiling position – usually around 1m from the cooking area. They are also appropriate for use in garages. In areas where vehicle exhausts are prevalent and a standard smoke alarm can cause a lot of false alarms.

Alarms with multiple sensors (stairwells and landings office spaces bedrooms, lounges, as well as hallways):

Combination alarms that have multiple sensors can be found with many different combinations that can be helpful because of the various characteristics the homes we live in. Combining smoke detectors with the rate of increase heat sensor can allow better detection of rapidly flaming fires as well as a lesser chance of false alarms when adding a carbon monoxide detector to a heat or smoke alarm can help safeguard yourself from this dangerous gas that human senses are unable to detect.

Their large response envelope allows the combined alarms to be suitable for nearly all areas of a house, including hallways, landings, bedrooms and living rooms. Be aware that while certain alarms with combined features have an energy sensor however, they are not suitable to be used in kitchens.

A note on mains-powered smoke alarms

Conforming to BS 539 Pt 6 grade D1 and D2, mains-powered smoke detectors and heat alarms have an additional battery, and they connect with each other in order that all alarms sound in the event of a fire. In the case of a failure to the mains the battery backup assures that the alarm continues to function until the mains supply is restored.

While smoke detectors that are part of the mains supply security for a long time without false alarms or malfunctions but it’s dangerous to think that they will last for ever. Smoke alarms and heat alarms must be replaced after 10 years as they begin to fail.

Types of batteries

Smoke and heat alarms that are mains-sourced that have an alkaline battery backup offer the most affordable (up in price) solution. Based on how frequently the alarms are tested and on how often they are activated (both legitimate as well as false alarms) the battery back-up is expected to last between 12 and 18 months before it is replaced. The manufacturers recommend that replacement of the batteries every twelve months to ensure that a run-down battery isn’t overlooked.

Certain mains-powered smoke alarms can be upgraded to a lithium back-up battery that is not rechargeable However, you must verify this in the user manual since lithium batteries operate differently, and some alarms are not compatible with both. While not sealed inside an alarm system, a lithium backup battery lasts between 5 and 10 years prior to replacement, except the radio interlinked alarms (2-5 years of life).

Then, the mains-powered alarms can be purchased with a rechargeable sealed-in lithium backup battery. The battery is built to last for the lifetime that the security alarm (10 to 10 years) and is not modified during its life. Additionally, it saves money from replacing batteries, the sealed lithium option is perfect for rental houses where the removal batteries or allowing them to go to zero is a concern.

Mains power feed

To get a mains feed smoke detectors, smoke alarms, and heat alarms can be connected to the closest lighting circuit, or via an individual circuit connected to the distribution panel. The fitting for lighting is typically preferred since it is less expensive and is less likely that it will be shut down to prevent being a victim of the “nuisance” of alarms that beep when the battery backup runs low. Care must be taken to ensure that the light switch doesn’t shut off power on the warnings.

General requirements for various properties

It is common to see the following requirements for smoke alarms:

Domestic Owner-occupied housing: BS5839 Part 6, Grade F2, Category LD2.
Extensions of owner-occupied, domestic housing: BS5839 Part 6 Grade D2 Category LD2
Domestic properties that are let and rented out: BS5839 part 6, Grade D1 Category LD2
Blocks of flats, or Houses with multiple occupations:
Common areas: BS 5839 Part 1 non-domestic fire alarm system BS Part 6 of 5839 Grade A, Category LD2/ L2
Individual dwellings: BS5839 Part 6, Grade D1, Categorization LD1 or LD2, and the sounder and an alarm system that includes a heat detector. community area alarm system
Any business of any size that is attached with residential dwelling(s): BS 5839 Part 1 fire alarm system for non-domestic dwellings as well as a sounder and heating detector inside the dwelling

What do the various Grades and Categories refer to?

Below are brief overviews of alarm Grades D and F, as and the three categories of systems for domestic homes. We recommend that you read our article on BS 5839 Part 6 for additional information on domestic alarms as well as our review of BS 5839 Part 1 for non-domestic properties.

Gradings F and D were separated into two parts as part of the latest update for 2019 to BS 8396-3. The first one refers to sealed tamper-proof batteries . two numbers are for battery replacements that are user-friendly.

Graduations D1 and D2

Mains-powered smoke detectors, interlinked as well as heat alarms. They are typically powered by cables from the closest lighting fixture, provided that the light switch doesn’t interrupt supply to the fire alarms. In order to create one interlink (all alarms sound simultaneously in the event of fire) they require either a cables connecting the two devices, which is separate of the circuit that powers them or an interlink radio connection.

Certain building control officers or local councils can accept the use of Grade F1 alarms that use radio-interlink as an alternative to mains-powered alarms. You must verify this prior to starting work to confirm that the alternatives are acceptable.

Graduations F1 and F2

Smoke detectors powered by batteries and heat alarms that are easy to install without any disruption, and with no requirement to hire an electrician. The majority of them are standalone devices, however some might have wireless interlinking capabilities using radio frequency. Additionally, a small number of them have hardwired interlink.